Pages

Wednesday, January 21, 2015

What happens when a d.c motor is connected across an ac supply?

What happens when a d.c motor is connected across an ac supply?


  • Since on ac supply, reactance will come in to play,the a.c supply will be offered impedance(not resistance) by the armature winding.consequently,with a.c supply,current will be much less.The motor will run but it would not carry the same load as it would on d.c. supply.
  • There would be more sparking at the brushes
  • Though motor armature is laminated as a rule, the field poles are not. consequently,eddy currents will cause the motor to heat up eventually burn on a.c. supply.

No comments: